The heartbeat of a pulsating star with a smart telescope – DY Pegasi with the Seestar S50

Using a 5 cm smart telescope on two autumn evenings, we built the light curve of DY Pegasi from more than 550 frames and timed two of its maxima to within a minute. The result shows that the star currently reaches maximum brightness about 1 minute later than the most recent published ephemeris predicts.
Variable star observing was long the domain of visual estimates and expensive CCD cameras. Smart telescopes such as the Seestar S50, however, can save every frame in FITS format, which makes real photometry possible. We wanted to find out what this small instrument can do with a rapidly varying star.

The heartbeat of a pulsating star with a smart telescope – DY Pegasi with the Seestar S50

The target: DY Pegasi

DY Pegasi is an SX Phoenicis-type pulsating variable that brightens again every 1 hour 45 minutes. The star rhythmically expands and contracts, and its brightness varies between about magnitude 10.0 and 10.6.

Because the period is so short, one or two complete cycles can be followed in a single evening. Its light curve is characteristic: a rapid rise is followed by a slower decline. The pulsation period has been measured for decades and is demonstrably decreasing slowly, so every new time of maximum is a valuable data point.

Observations

The frames were taken on two evenings with a Seestar S50 smart telescope (5 cm objective, 250 mm focal length, colour sensor), each with a 10-second exposure.

Date

Time span (UT)

Frames

Usable

14 November 2026

17:48–20:28

464

437

7 November 2026

20:15–21:20

130

109

The telescope also recorded dark frames alongside the light frames. The 14 November series was long enough to cover more than one full pulsation cycle.

How did the frames become a light curve?

The method is differential photometry: on every frame, the variable's light is compared with constant stars in the same field. This way changes in the atmosphere (haze, thin cloud, transparency) largely cancel out.

  1. Calibration frames: each frame had the dark frame closest to its sensor temperature subtracted.

  2. Alignment: the Seestar has an alt-azimuth mount, so the field rotates during the evening. Every frame was aligned to a reference frame using the star pattern.

  3. Photometry: stellar light was measured in a small circular aperture with the sky background subtracted. We used the green channel, which is closest to the V filter (AAVSO designation: TG).

  4. Calibration: four comparison stars (000-BJR-290, -288, -292, -289) from AAVSO sequence X43370AMMN were used. A fifth star (000-BJR-294) served as the check star.

  5. Filtering: frames in which the comparison stars suddenly faded, a sign of passing cloud, were discarded.

  6. Timing: the mid-exposure times were converted to Heliocentric Julian Date (HJD), as is customary for timing pulsating stars.

The light curve

The 14 November light curve clearly shows two maxima and the minimum between them: DY Pegasi varied between V(TG) magnitude 10.04 and 10.61. The rise takes about 20 minutes, while the decline lasts several times longer.

The check star shows how reliable the measurements are: against its catalogue value of 12.041 we measured 12.050, with a frame-to-frame scatter of 0.06 magnitude. For 10-second frames through a 5 cm telescope, that is a good result.

When was maximum? The O–C

On both evenings maximum occurred about 1.2–1.3 minutes later than the most recent prediction. We compared our timings with the latest ephemeris from Thomas Berthold's 2024 analysis (OEJV 254).

Date

Maximum (UT)

HJD

O–C

14 November 2026

19:36:18

2461359.3198 ± 0.0002

+1.2 min

14 November 2026

17:51:21

2461359.2469 ± 0.0003

+1.2 min

7 November 2026

approx. 21:19

2461352.3920 ± 0.0004

+1.3 min

O–C (observed minus calculated) is the simplest test of a variable star's “clock”. If the star's period changes, the O–C values drift over the years.

The most reliable value is the 14 November maximum at 19:36, because the observations cover both sides of it. The 7 November maximum fell at the very end of the series, so it was estimated by fitting the shape of the 14 November light curve. Nearly identical O–C values, obtained independently a week apart, suggest the offset is real.

Lessons and plans

A smart telescope can deliver scientifically useful variable star measurements, provided the frames are reduced carefully. A few tips for Seestar owners:

  • Save the individual frames as FITS. The stacked image produced by the Seestar is not suitable for photometry.

  • Observe at least one full cycle. For DY Pegasi that is 2 hours, which guarantees at least one maximum covered on both sides.

  • Times of maximum can be predicted from the ephemeris, so observations can be scheduled in advance.

  • Because of field rotation, stars near the edge of the field drift out of the frame from time to time; choose comparison stars near the centre.

The measurements have been prepared in AAVSO Extended format, ready for submission to the international database. The next goal is to collect more nights covering full cycles, so that the O–C can be followed over the longer term.

Sources

Share Facebook
T
Tibor Csörgei

Club Member